Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 352
Filtrar
1.
J Med Case Rep ; 18(1): 228, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38720351

RESUMO

BACKGROUND: Mesonephric adenocarcinoma is an extremely rare subtype of uterine cervical cancer that is associated with a poor prognosis and for which a standardized treatment protocol has not been established. Carbon ion radiotherapy (CIRT) is an emerging radiotherapy modality that has been shown to have a favorable anti-tumor effect, even for tumors resistant to conventional photon radiotherapy or chemotherapy. However, there is no report on CIRT outcomes for mesonephric adenocarcinoma of the uterine cervix. CASE PRESENTATION: We treated a 47-year-old Japanese woman with mesonephric adenocarcinoma of the uterine cervix (T2bN0M0 and stage IIB according to the 7th edition of the Union for International Cancer Control and International Federation of Gynecology and Obstetrics, respectively) with CIRT combined with brachytherapy and concurrent chemotherapy. CIRT consisted of whole pelvic irradiation and boost irradiation to the gross tumor; 36.0 Gy (relative biological effectiveness [RBE]) in 12 fractions and 19.2 Gy (RBE) in 4 fractions, respectively, performed once a day, four times per week. Computed tomography-based image-guided adaptive brachytherapy was performed after completion of CIRT, for which the D90 (i.e., the dose prescribed to 90% of the target volume) for the high-risk clinical target volume was 20.4 Gy in a total of 3 sessions in 2 weeks. A weekly cisplatin (40 mg/m2) dose was administered concomitantly with the radiotherapy for a total of five courses. From 4 months post-CIRT, the patient developed metastasis of the lung, with a total of 10 lung metastases over 70 months; these lesions were treated on each occasion by photon stereotactic body radiotherapy and/or systemic therapy. At 8 years from initial treatment (i.e., 2 years after the last treatment), the patient is alive without any evidence of recurrence and maintains a high quality of life. CONCLUSIONS: This is the first report of CIRT for treatment of mesonephric adenocarcinoma of the uterine cervix. The present case indicates the potential efficacy of CIRT in combination with brachytherapy for treatment of this disease.


Assuntos
Adenocarcinoma , Braquiterapia , Radioterapia com Íons Pesados , Neoplasias do Colo do Útero , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Adenocarcinoma/radioterapia , Adenocarcinoma/patologia , Radioterapia com Íons Pesados/métodos , Braquiterapia/métodos , Resultado do Tratamento , Quimiorradioterapia/métodos
2.
Jpn J Radiol ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568430

RESUMO

OBJECTIVE: This study aimed to show the results of radical radiation therapy (RT) and concurrent chemoradiotherapy (CCRT) for vulvar cancer (VC) based on data from a Japanese nationwide survey. MATERIALS AND METHODS: We collected data from 108 institutions on cases of VC diagnosed between January 2001 and December 2010. Patients with histologically proven squamous cell carcinoma and adenocarcinoma with curative intent were selected, and 172 patients with VC were included in this study. The collected data were analyzed for overall survival (OS) using the Kaplan-Meier method. Univariate and multivariate analyses were performed to examine the prognostic factors for patients with VC. RESULTS: The median follow-up period was 16.8 (range; 3.2-154.8) months. Fifty-five patients received CCRT, and 117 patients received RT alone. The 2-year OS rates (95% confidence interval [CI]) for stages I, II, III, and IV were 77.9% (55.8-100.0), 71.9% (53.8-89.9), 55.4% (42.5-68.3), and 41.5% (27.3-55.7) respectively. Univariate analyses showed that the FIGO stage (p = 0.001), tumor diameter (p = 0.005), and lymph node (LN) status (p = 0.001) were associated with OS. The concurrent use of chemotherapy resulted in a significantly longer OS in Stage III (p = 0.013). Multivariate analysis showed that the hazard ratios (95% CI) for tumor diameter, positivity for LN metastasis, and RT alone (no concurrent chemotherapy) were 1.502 (1.116-2.021), 1.801 (1.287-2.521), and 1.936 (1.187-3.159), respectively. CONCLUSIONS: Our analysis revealed that CCRT should be recommended, especially for Stage III VC patients. Further studies are warranted to determine who benefits from CCRT, considering primary tumor size and LN status. The study was registered at the University Hospital Medical Information Network (protocol number: UMIN000017080) on April 8th, 2015.

3.
IEEE Open J Eng Med Biol ; 5: 157-162, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487101

RESUMO

Introduction: While carbon ion radiotherapy is highly effective in cancer treatment, it has a high risk of causing soft error, which leads to malfunctions in cardiac implantable electrical devices (CIEDs). To predict the risk of malfunction prior to treatment, it is necessary to measure the reaction cross-sections and contributions to the soft error of secondary particles generated during treatments. Methods: A field-programmable gate array was used instead of CIEDs to measure soft errors by varying the energy spectrum of secondary particles. Results and discussion: The reaction cross-sections measured for each secondary particle were 3.0 × 10-9, 2.0 × 10-9, 1.3 × 10-8, and 1.5 × 10-8 [cm2/Mb] for thermal neutrons, intermediate-energy neutrons, high-energy neutrons above 10 MeV, and protons, respectively. The contribution of high-energy neutrons was the largest among them. Our study indicates that to reduce the risk of soft errors, secure distance and appropriate irradiation directions are necessary.

4.
BMC Cancer ; 24(1): 300, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443871

RESUMO

BACKGROUND: The quality of life of patients is an important consideration when selecting treatments for localized prostate cancer (PCa). We retrospectively compared sexual function after robot-assisted radical prostatectomy (RARP) and carbon-ion radiotherapy (CIRT) using propensity score matching. METHODS: In total, 127 Japanese PCa patients treated with RARP and 190 treated with CIRT monotherapy were evaluated. We evaluated the Expanded Prostate Cancer Index Composite (EPIC) score before treatment and 12 and 24 months after treatment. After propensity score matching, data from 101 patients from each group were analyzed. The study protocol was approved by the Institutional Review Board of Gunma University Hospital (no. IRB2020-050, 1839). RESULTS: After propensity score matching, the mean EPIC sexual function summary scores in the RARP and CIRT groups were 46.4 and 48.2, respectively. At 12 and 24 months after treatment, these scores were 27.9 (39.9% decrease) and 28.2 (39.2% decrease) in the RARP group and 41.4 (14.1% decrease) and 41.6 (13.7% decrease) in the CIRT group, respectively. Both groups demonstrated significantly decreased scores after 12 and 24 months of treatment compared to before treatment (all p < 0.05). At 12 and 24 months, the sexual function summary score was significantly higher in the CIRT group than in the RARP group (p < 0.001). CONCLUSIONS: There was a smaller decrease in the EPIC sexual function score in the CIRT group than in the RARP group. These results provide useful information for treatment decision-making of Japanese PCa patients.


Assuntos
Neoplasias da Próstata , Robótica , Masculino , Humanos , Japão , Pontuação de Propensão , Qualidade de Vida , Estudos Retrospectivos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Prostatectomia/efeitos adversos , Carbono
5.
J Radiat Res ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38544297

RESUMO

This study assessed the significance of hands-on-training (HoT) and questionnaire-based surveys on 3D image-guided brachytherapy (3D-IGBT) and a combination of intracavitary and interstitial brachytherapy, the so-called 'hybrid' BT (HBT), in uterine cervical cancer. In October 2023, 29 radiation oncologists, nurses, radiologic technologists and medical physicists from 10 Japanese facilities participated in an HoT on 3D-IGBT and HBT. Questionnaires were distributed to each participant before and after the HoT, and feedback was obtained through online channels. The questionnaire response rate was 83% (24/29), with at least one participant responding from each facility. 'Insertion of applicators and needles', 'human resource shortage' and 'pain relief and sedation' were the primary concerns of radiation oncologists. 'Applicator reconstruction', ' optimization of dwell positions', ' treatment planning' and ' human resource shortages ' were the primary concerns of radiological technologists and medical physicists. The HoT content was adjusted according to the results of preliminary surveys. The concerns expressed by the participants were addressed during the lectures and practical training. Significant reductions in anxiety were observed toward all items of the 10-point self-assessment after the HoT, regardless of the profession. The average score on satisfaction with the HoT (on a 10-point scale) was 9.52 (minimum of 8 and maximum of 10). In conclusion, HoT tailored in response to a pre-questionnaire-based survey effectively reduced participants' anxiety regarding the implementation of 3D-IGBT and HBT.

6.
J Radiat Res ; 65(2): 168-176, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38151923

RESUMO

This study aimed to assess the current state of brachytherapy (BT) resources, practices and resident education in Japan. A nationwide survey was undertaken encompassing 177 establishments facilitating BT in 2022. Questionnaires were disseminated to each BT center, and feedback through online channels or postal correspondence was obtained. The questionnaire response rate was 90% (159/177), and every prefecture had a response in at least one center. The number of centers in each prefecture ranged from 0.6 to 3.6 (median: 1.3) per million population. The annual number of patients in each center ranged from 0 to 272 (median: 31). While most prefectures provided intracavitary (IC) BT for gynecological cancers and interstitial (IS) BT for prostate cancer, only one-third of the prefectures provided IS BT for cancer sites other than the prostate. The institutional image-guided BT implementation rate was 71%. IC and IS BT was performed for 15.4% of IC BT cases of gynecological cancer. Only 47% of the BT training centers answered that they could provide adequate training in BT for residents. The most common reason for this finding was the insufficient number of patients in each center. The results show that, although BT has achieved uniformity in terms of facility penetration, new technologies are not yet widespread enough. Furthermore, IS BT, which requires advanced skills, is limited to a few BT centers, and considerable number of BT training centers do not have sufficient caseloads to provide the necessary experience for their residents.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Masculino , Feminino , Humanos , Braquiterapia/métodos , Japão , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
7.
Anticancer Res ; 43(11): 4873-4878, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37909964

RESUMO

BACKGROUND/AIM: Dose distributions of carbon-ion radiotherapy (C-ion RT) have been created with the relative biological effectiveness (RBE) of human salivary gland cells (HSG). However, no dose distributions have been created using various tumor cell-specific RBE values. Hence, we conducted in vitro experiments to determine the RBE of human osteosarcoma cells (U2OS) and used this RBE value (RBEU2OS) to calculate the dose distribution for C-ion RT. MATERIALS AND METHODS: To obtain RBE values for various linear energy transfer (LET) levels, we exposed U2OS cells to different doses of X-rays and varying doses and LET levels of C-ion beams (13, 30, 50, and 70 keV/µm). Subsequently, we converted the RBE of HSG (RBEHSG) to RBEU2OS in the treatment planning system and reconstructed the dose distribution for a typical osteosarcoma case. We performed a dose-volume histogram (DVH) analysis, evaluating the percentage of the minimum dose that covered 98%, 50%, and 2% (D98%, D50%, and D2%, respectively), as well as the homogeneity index [HI; calculated as (D2%-D98%)/D50%]. RESULTS: The RBEU2OS values for C-ion beams with LET of 13, 30, 50, and 70 keV/µm were 1.77, 2.25, 2.72, and 4.50, respectively. When comparing DVH parameters with the planning target volume, we observed the following values: D98%, D50%, D2%, and HI for RBEHSG were 64.1, 70.1, 72.4 Gy (RBE), and 0.12, respectively. For RBEU2OS, these values were 86.2, 95.0, 107.9 Gy (RBE), and 0.23, respectively. CONCLUSION: We utilized RBEU2OS to calculate the dose distribution of carbon ion radiotherapy, revealing potential degradation in dose distribution and particularly worsening of the HI.


Assuntos
Neoplasias Ósseas , Radioterapia com Íons Pesados , Osteossarcoma , Humanos , Eficiência Biológica Relativa , Osteossarcoma/radioterapia , Neoplasias Ósseas/radioterapia , Carbono
8.
Front Oncol ; 13: 1107703, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37655110

RESUMO

Breast cancer is the most common malignant tumor in female patients. Along with surgery, radiotherapy is one of the most commonly prescribed treatments for breast cancer. Over the past few decades, breast cancer radiotherapy technology has significantly improved. Nevertheless, related posttherapy complications should not be overlooked. Common complications include dose-related coronary toxicity, radiation pneumonia, and the risk of second primary cancer of the contralateral breast. Particle radiotherapy with protons or carbon ions is widely attracting interest as a potential competitor to conventional photon radiotherapy because of its superior physical and biological characteristics. This article summarizes the results of clinical research on proton and carbon-ion radiotherapy for treating breast cancer.

9.
Phys Med Biol ; 68(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37738990

RESUMO

Objective. Dose distribution estimation during the treatment course is essential for carbon ion radiotherapy because beam ranges are highly sensitive to density changes along beam paths, triggering the adaptive re-planning at an appropriate time. This study aims to investigate the feasibility of evaluating daily dose distributions using the divided-volume matching (DVM) technique without additional daily computed tomography (CT) scans for adaptive carbon ion radiotherapy for liver tumors.Approach. Phantom and patient data were included in this study. The developed in-house DVM software generated DVM CTs based on the existing resources, the planning CT, and orthogonal two-dimensional (2D) setup images. Bone matching (BM) and tumor matching (TM) are the two common ways of patient positioning correction to determine the isocenter for the irradiation of the day. We compared the dose distributions between DVM and in-room CTs with different isocenters based on BM or TM to verify whether the DVM CTs sufficiently represent the in-room CTs for daily dose distribution evaluations.Main results. For the phantom study, the clinical target volume coverage (V95%) differences between the in-room and the DVM CTs were <2%, and their dose distribution patterns were similar. For clinical data, the 3%/3 mm gamma passing rates were over 96%, and the planning target volume coverage (V95%) differences were <3% between the in-room and DVM CTs in nine out of ten patients. With different isocenters, the dose coverage of the DVM CT changed consistently with those of the in-room CT.Significance. The DVM technique enabled the evaluation of daily dose distributions without additional CT scans and was shown to be feasible in carbon ion radiotherapy for liver tumors.

11.
Cancer Sci ; 114(9): 3679-3686, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37391921

RESUMO

Reports on the therapeutic efficacy and safety of carbon-ion radiotherapy (C-ion RT) for oligometastatic liver disease are limited, with insufficient evidence. This study aimed to evaluate the clinical outcomes of C-ion RT for oligometastatic liver disease at all Japanese facilities using the nationwide cohort data. We reviewed the medical records to obtain the nationwide cohort registry data on C-ion RT between May 2016 and June 2020. Patients (1) with oligometastatic liver disease as confirmed by histological or diagnostic imaging, (2) with ≤3 synchronous liver metastases at the time of treatment, (3) without active extrahepatic disease, and (4) who received C-ion RT for all metastatic regions with curative intent were included in this study. C-ion RT was performed with 58.0-76.0 Gy (relative biological effectiveness [RBE]) in 1-20 fractions. In total, 102 patients (121 tumors) were enrolled in this study. The median follow-up duration for all patients was 19.0 months. The median tumor size was 27 mm. The 1-year/2-year overall survival, local control, and progression-free survival rates were 85.1%/72.8%, 90.5%/78.0%, and 48.3%/27.1%, respectively. No patient developed grade 3 or higher acute or late toxicity. C-ion RT is a safe and effective treatment for oligometastatic liver disease and may be beneficial as a local treatment option in multidisciplinary treatment.


Assuntos
Radioterapia com Íons Pesados , Neoplasias Hepáticas , Radioterapia (Especialidade) , Humanos , Radioterapia com Íons Pesados/efeitos adversos , Radioterapia com Íons Pesados/métodos , Japão , Neoplasias Hepáticas/radioterapia , Estudos Multicêntricos como Assunto , Intervalo Livre de Progressão , Estudos Retrospectivos , Resultado do Tratamento
12.
Heliyon ; 9(6): e16684, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37292314

RESUMO

This pilot study aimed primarily to evaluate plasma levels of a novel metabolite, creatine riboside, in patients with cervical cancer (discovery and validation cohorts, n = 11 for each) compared with non-cancer subjects (controls, n = 30). We found that the pre-treatment plasma creatine riboside level was significantly higher in the discovery cohort than in controls. The cut-off value determined from the discovery cohort distinguished 90.9% of the patients in the validation cohort from controls. Unbiased principal component analysis of plasma metabolites in high-creatine riboside samples demonstrated enrichment of pathways involved in arginine and creatine metabolism. These data indicate the potential utility of plasma creatine riboside as a biomarker of cervical cancer.

13.
Pract Radiat Oncol ; 13(4): 265-266, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37391232

RESUMO

A 60-year-old woman received carbon ion radiotherapy (C-ion RT) (70.4 Gy [relative biological effectiveness]/16 fr) for undifferentiated pleomorphic sarcoma (UPS) (T4bN0M0) in the left pterygopalatine fossa. After 26 months, left parotid resection and left neck dissection were performed for lymph node metastasis in the left parotid gland (no irradiation field). Pathological findings revealed a lymph node with UPS metastasis in the left parotid gland. However, no other metastases in the left cervical lymph node or vascular invasion were observed. Four months after surgery, magnetic resonance imaging revealed an invasion of the left internal jugular vein. Pathological examination of the vascular lesion was not possible because the patient did not consent to surgery. Undifferentiated pleomorphic sarcoma most commonly metastasizes to the lung, and there is currently no known report of vascular invasion. In this case, vascular invasion possibly developed due to changes in the perivascular tissues after the left neck dissection, which may have facilitated tumor invasion into the vascular wall. Based on the images and the clinical course, a rare condition for vascular invasion from UPS recurrence was considered.


Assuntos
Veias Jugulares , Sarcoma , Feminino , Humanos , Pessoa de Meia-Idade , Linfonodos , Metástase Linfática , Glândula Parótida , Sarcoma/radioterapia
14.
Anticancer Res ; 43(7): 2975-2984, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37351961

RESUMO

BACKGROUND/AIM: This study aimed to develop an improved algorithm for linear energy transfer (LET) estimation in carbon ion radiotherapy (CIRT) using relative biological effectiveness (RBE) and to establish a clinical pipeline for LET assessment. MATERIALS AND METHODS: New approximation functions for LET versus RBE were developed for the overkill region. LET estimation performance was examined at two facilities (A and B) using archival- and Monte Carlo simulation-derived LET data, respectively, as a reference. A clinical pipeline for LET assessment was developed using Python and treatment planning systems (TPS). RESULTS: In dataset A, LET estimation accuracy in the overkill region was improved by 80.0%. In dataset B, estimation accuracy was 2.3%±0.67% across 5 data points examined. LET distribution and LET-volume histograms were visualized for multiple CIRT plans. CONCLUSION: The new algorithm showed a greater LET estimation performance at multiple facilities using the same TPS. A clinical pipeline for LET assessment was established.


Assuntos
Radioterapia com Íons Pesados , Terapia com Prótons , Humanos , Transferência Linear de Energia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Carbono
15.
Cancers (Basel) ; 15(10)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37345195

RESUMO

Systemic chemotherapy has significantly improved in recent years. In this study. the clinical impact of carbon-ion radiotherapy (CIRT) with concurrent chemotherapy for locally advanced unresectable pancreatic cancer (URPC) was evaluated. METHODS: Patients with URPC who were treated with CIRT between January 2016 and December 2020 were prospectively registered and analyzed. The major criteria for registration were (1) diagnosed as URPC on imaging; (2) pathologically diagnosed adenocarcinoma; (3) no distant metastasis; (4) Eastern Cooperative Oncology Group performance status of 0-2; (5) tumors without gastrointestinal tract invasion; and (6) available for concurrent chemotherapy. Patients who received neoadjuvant chemotherapy (NAC) for more than one year prior to CIRT were excluded. RESULTS: Forty-four patients met the inclusion criteria, and thirty-seven received NAC before CIRT. The median follow-up period of living patients was 26.0 (6.0-68.6) months after CIRT. The estimated two-year overall survival, local control, and progression-free survival rates after CIRT were 56.6%, 76.1%, and 29.0%, respectively. The median survival time of all patients was 29.6 months after CIRT and 34.5 months after the initial NAC. CONCLUSION: CIRT showed survival benefits for URPC even in the multiagent chemotherapy era.

16.
Cancers (Basel) ; 15(9)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37173985

RESUMO

Carbon-ion radiotherapy (CIRT) is one of the most effective radiotherapeutic modalities. This study aimed to select robust-beam configurations (BC) by water equivalent thickness (WET) analysis in passive CIRT for pancreatic cancer. The study analyzed 110 computed tomography (CT) images and 600 dose distributions of eight patients with pancreatic cancer. The robustness in the beam range was evaluated using both planning and daily CT images, and two robust BCs for the rotating gantry and fixed port were selected. The planned, daily, and accumulated doses were calculated and compared after bone matching (BM) and tumor matching (TM). The dose-volume parameters for the target and organs at risk (OARs) were evaluated. Posterior oblique beams (120-240°) in the supine position and anteroposterior beams (0° and 180°) in the prone position were the most robust to WET changes. The mean CTV V95% reductions with TM were -3.8% and -5.2% with the BC for gantry and the BC for fixed ports, respectively. Despite ensuring robustness, the dose to the OARs increased slightly with WET-based BCs but remained below the dose constraint. The robustness of dose distribution can be improved by BCs that are robust to ΔWET. Robust BC with TM improves the accuracy of passive CIRT for pancreatic cancer.

18.
Artigo em Inglês | MEDLINE | ID: mdl-37088970

RESUMO

AIM: This study aimed to report initial results of hypofractionated carbon-ion radiotherapy (C-ion RT) for inoperable upper tract ureteral cancer. METHODS: Retrospective chart review was performed for five consecutive patients with medically inoperable ureter cancer that was treated with radical C-ion RT between December 2013 and December 2014. The median age of the patients was 80 years (range, 68-84 years). The reasons for inoperability were advanced age, post-contralateral nephrectomy, alcoholic cirrhosis, both advanced age and contralateral renal function degeneracy, and pneumonia. The median size of tumor was 2.8 cm (range, 2.2-4.0 cm). Diagnostic imaging did not identify lymph node metastases or distant metastases in any case. All patients underwent C-ion RT (52.8 Gy relative biological effectiveness; 12 fractions in 3 weeks). The clinical target volume encompassed the growth tumor volume with a 5-mm margin bilaterally; there was a 40-mm margin craniocaudally but the clinical target volume did not encompass the whole ureter. RESULTS: Within a median follow-up time of 32.9 months (range, 24-36 months), two patients died and three remained alive. Neither local recurrence nor regional lymph node metastases were observed. Secondary bladder tumor was observed in four patients, and one patient had a liver metastasis. Grade 1 hematuria was observed in two patients, and Grade 3 pyelonephritis was observed in one patient as acute toxicity. Ureteral obstruction was observed in two patients. CONCLUSION: C-ion RT might be a useful treatment option for inoperable ureter cancer.

20.
In Vivo ; 37(3): 1016-1021, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37103115

RESUMO

BACKGROUND/AIM: This study aimed to confirm the relative biological effectiveness (RBE) values of the proton beam therapy (PBT) system installed in Shonan Kamakura General Hospital. MATERIALS AND METHODS: Clonogenic cell-survival assays were performed with a human salivary gland (HSG) cell line, a human tongue squamous-cell carcinoma cell line (SAS), and a human osteosarcoma cell line (MG-63). Cells were irradiated with proton beams and X-rays with different doses (1.8, 3.6, 5.5, and 7.3 Gy for proton beams, and 2, 4, 6, and 8 Gy for X-rays). Proton beam irradiation used spot-scanning methods and three different depths (at the proximal, center, and distal sides of the spread-out Bragg peak). RBE values were obtained from a comparison of the dose that resulted in a surviving fraction of 10% (D10). RESULTS: D10 of proton beams at the proximal, center, and distal sides and X-rays in HSG were 4.71, 4.71, 4.51, and 5.25 Gy, respectively; those in SAS were 5.08, 5.04, 5.01, and 5.59 Gy, respectively; and those in MG-63 were 5.36, 5.42, 5.12, and 6.06 Gy, respectively. The RBE10 values at the proximal, center, and distal sides in HSG were 1.11, 1.11, and 1.16 respectively; those in SAS were 1.10, 1.11, and 1.12, respectively; and those in MG-63 were 1.13, 1.12, and 1.18, respectively. CONCLUSION: RBE10 values of 1.10-1.18 were confirmed by in vitro experiments using the PBT system. These results are considered acceptable for clinical use in terms of therapeutic efficacy and safety.


Assuntos
Terapia com Prótons , Humanos , Prótons , Relação Dose-Resposta à Radiação , Eficiência Biológica Relativa , Hospitais Gerais , Sobrevivência Celular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA